  1. Deck, porch, patio, balcony? - The Building Code Forum

    Nov 1, 2012 · I am asking for your opinion about the various terms used in the IRC to describe exterior walking surfaces: Deck, Porch, Patio, Balcony. After 16 years of teaching deck codes and 10 years …

  2. CBC exterior 3rd floor balcony egress | The Building Code Forum

    Oct 30, 2024 · the balcony is 2224 sq ft. it is like a area, when the board member take a break during the meeting, can breath some fresh air, or if the board room holding an event, wine tasting, …

  3. Can you establish egress from a bedroom to a 2nd floor balcony

    Nov 24, 2023 · Unless the balcony offers a compliant exterior exit stair, it would not be a "means of egress" but it might qualify as an exterior area of refuge, or the door/window leading to the balcony …

  4. balcony | The Building Code Forum

    Jun 9, 2025 · Balcony location If an "L" shaped building has a balcony terminating at the inside leg of the building portion that extends past the balcony edge at a right angle, then the balcony complies with …

  5. One balcony joist bay vent, or two required?

    Nov 2, 2009 · There was a previous thread where we had discussed continuous balcony vents, and up until now, I assumed that only one continuous vent was required per CBC 2304.12.2.5, which states: …

  6. How to vent a balcony with finished living space below?

    Jan 30, 2013 · I have a 10'x12' balcony with half-walls on three sides and a full wall with a sliding glass door to living space on the 4th side. Below the balcony is finished living space. My concern is how to …

  7. Vents at fire rated balcony construction - The Building Code Forum

    Nov 2, 2009 · Picture a type V-A apartment building with private balconies stacked over each other. You've used a membrane assembly (say, type X purple gyp board with stucco) on the underside of …

  8. Receptacles at balconies - The Building Code Forum

    Jan 20, 2012 · A balcony, deck or porch of a certain size requires a receptacle and many configurations below 20 sq. ft. must be included. That is not all inclusive. At a point, the size and or configuration of …

  9. Exterior Balcony Egress | The Building Code Forum

    Nov 22, 2016 · I have an exterior balcony off of a 2nd floor lunch area in a school. I realized that there is no egress when the building is locked up because the balcony is only accessed from the adjacent …

  10. bedroom egress to a balcony - The Building Code Forum

    Apr 16, 2018 · We would like to replace a window with french doors that lead to a balcony. Can this be considered a possible fire escape egress ?